TeltoCharge
New electric vehicle smart charger manufactured by Teltonika Energy. All models now with solar energy support!
Charger only, installation not included
From: £742.88 inc. VAT
Contact us directly for a quantity discount
The TeltoCharge EVC16X range combines aesthetics, functionality, and top-tier technical features with the goal of delivering the latest technological advancements to the market.
The charger is controlled via an app, which connects with the phone through Bluetooth, allowing for a seamless integration and user experience.
Discover cutting-edge features tailored for the United Kingdom market:
CT Clamps or Energy Meter Support: Allows precise energy monitoring and conservation.
Solar Charging Support: Supports eco-friendly solar charging.
Dynamic Load Balancing: Prevents system overload by evenly distributing power.
CE & UKCA certified
36 months warranty
Made in EU
* Mobile communication in models with a modem provides the charger with several functions: the ability to connect to the OCPP platform when there is no Wi-Fi and the option for customers to receive notifications on their phone when the anti-tamper function is triggered.
Dimensions without cable | 170x341x97 mm |
Weight without cable | 2,8 kg |
Operating temperature | -30°C – +50°C |
IP rating | IP55 |
IK rating | IK10 |
Certification | CE & UKCA compliant |
Standards | 2014/53/EU, BS EN IEC 61851-1, IEC 61851-21-2, EN 62311 |
Cable length | 5 m |
Connectivity | LAN, WiFi, Bluetooth, 4G/LTE (CAT1), SIM card not included |
OCPP compliant | 1.6 – Yes |
Mobile App | Yes |
NFC | Yes |
PEN Fault protection | Yes (7.4kW version only) |
Solar Energy Support | Yes |
AC INPUT SPECIFICATIONS | |||
7,4 kW | 11 kW | 22 kW | |
Input AC power connection | 1 phase | 1 or 3 phases | 1 or 3 phases |
Maximum Current | 32A | 16A | 32A |
PEN Fault Protection | Yes | No | No |
Input voltage | (L-N) 230 ± 10% VAC |
3 phase: (L-L) 400 ± 10% VAC (L-N) 230 ± 10% VAC |
|
1 phase: (L-N) 230 ± 10% VAC | |||
Rated frequency | 50 / 60 HZ | ||
Standby power consumption | 4 W | ||
Earth (ground) fault protection | Integrated RDC-DD 6mA DC protection. DC protection was designed according to IEC 62955 2. Integral PEN fault protection (7.4 kW only) | ||
Overvoltage category | CAT II | ||
Protection against electric shock | Class I | ||
Solar Energy Support | Yes | ||
AC Output specifications | |||
AC output voltage range | (L-N) 230 ± 10% VAC |
3 phase: (L-L) 400 ± 10% VAC (L-N) 230 ± 10% VAC |
|
1 phase: (L-N) 230 ± 10% VAC | |||
Connection Standard |
Type 2 cable Type 2 socket |
||
Power Cable | |||
Maximum cable diameter | 11-17.5 mm | ||
Maximum wire cross section | 6-10 mm2 | ||
Cabkle type | H05V2V2 or better |
Note 1: Apply included cable end ferrules during installation
Note 2: External RCD type A required